School Instrument India is a leading Bilirubin Meter Manufacturer,and suppliers in India, Bilirubin Meter Uruguay (Montevideo), Bilirubin Meter Uzbekistan (Tashkent), Bilirubin Meter Venezuela (Caracas), Bilirubin Meter Vietnam (Hanoi), Bilirubin Meter Yemen (Sana'a), Bilirubin Meter Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

Platform: bench-top, open, fully automatic system
With digital alphanumeric display and integrated printer
Accuracy of measurement, approximately: 5%
Sample type: whole blood, volume: 10ul
Analysis time: 3 seconds
Automated calibration and self-diagnosis
Power requirements: 220V/50Hz, with voltage surge protection
Energy saving mode (stand by) after 30 minutes
Humidity up to 80% and operating temperature 15C to 35C
Data management complete with built-in software and possibility to print data or send data to PC
Quality control flags abnormal results, auto-calibration
Suitable for intensive care, emergency departments or other low-volume settings in hospitals

   